Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
Odovtos (En línea) ; 24(1)abr. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386577

RESUMO

Abstract This study evaluated the effects of alternative self-etch application modes on resin-dentin microtensile bond strength (µTBS) of three commercially available "no wait" concept universal adhesives. In this study extracted impacted non-carious human third molars were used. The flat surfaces were prepared in mid-coronal dentin and prepared with a 600-grit SiC paper. The three universal adhesives that were used are as follows: Clearfil Universal Bond Quick (CUQ, Kuraray Noritake, Japan), G-Premio Bond (GPB, GC Corp, Japan), and a self-curing universal adhesive "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japan). The following three different application procedures were used for the dentin surfaces: the adhesives were applied and immediately subjected to air-dry; the adhesives were applied followed by a 10-second wait; or the adhesives were rubbed for 10 seconds. Then composite resin was applied to the dentin surface and light cured. After storage in 37°C distilled water for 24 h, all the bonded teeth were cut into 1mm² sections using a low-speed diamond saw (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turkey) under running water (n=15). The sections were subjected to a tensile force at a crosshead speed of 1mm/min in a testing apparatus (Microtensile Tester, Bisco, IL, USA) and µTBS values were measured. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test. Failure modes were analyzed under a stereomicroscope. Prolonged application time significantly affected the µTBS (p<0.005). A significant increase of µTBS on active application was observed for CUQ and GPB. The TUB with an active application had a significantly lower µTBS value compared with the other adhesives. Prolonged application time caused significant improvement of bond strength in all adhesives. The active application is effective at increasing the dentin bond strength except for TUB.


Resumen Este estudio evaluó los efectos de los modos alternativos de aplicación de adhesivos de autograbado en la resistencia de la unión microtensil entre resina y dentina (µTBS) de tres adhesivos universales de concepto "no espera" disponibles en el mercado. En este estudio se utilizaron terceros molares humanos impactados que fueron extraídos. Las superficies planas se prepararon en la dentina coronal media y se prepararon con un papel SiC de 600 granos. Los tres adhesivos universales que se utilizaron son los siguientes: Clearfil Universal Quick Bond (CUQ, Kuraray Noritake, Japón), G-Premio Bond (GPB, GC Corp, Japón), y un adhesivo universal autopolimerizable "Tokuyama Universal Bond" (TUB; Tokuyama Dental, Japón). Se utilizaron los tres procedimientos de aplicación siguientes para las superficies dentinarias: se aplicaron los adhesivos y se sometieron inmediatamente a un secado al aire; se aplicaron los adhesivos y se esperó 10 segundos; o se frotaron los adhesivos durante 10 segundos. Luego se aplicó resina compuesta a la superficie dentinaria y se fotopolimerizó. Después de su almacenamiento en agua destilada a 37°C durante 24 h, todos los dientes unidos se cortaron en secciones de 1mm² utilizando una sierra de diamante de baja velocidad (Micracut 125 Low Speed Precision Cutter, Metkon, Bursa, Turquía) bajo agua corriente (n=15). Las secciones fueron sometidas a una fuerza de tracción a una velocidad de cruceta de 1mm/min en una máquina de prueba universal (Microtensile Tester, Bisco, IL, USA) y se midieron los valores de µTBS. Los datos fueron analizados utilizando la prueba de Kruskal-Wallis y la prueba U de Mann-Whitney. Los modos de falla fueron analizados bajo un estereomicroscopio. El prolongado tiempo de aplicación afectó significativamente a los µTBS (p<0,005). Se observó un aumento significativo de µTBS en la aplicación activa para el CUQ y el GPB. El TUB con una aplicación activa tuvo un valor de µTBS significativamente más bajo comparado con los otros adhesivos. El tiempo de aplicación prolongado causó una mejora significativa de la fuerza de adhesión en todos los adhesivos. La aplicación activa es efectiva para aumentar la fuerza de adhesión de la dentina, excepto para el TUB.


Assuntos
Cimentos Dentários/análise
2.
Arq. odontol ; 57: 8-16, jan.-dez. 2021. tab
Artigo em Português | LILACS, BBO | ID: biblio-1150644

RESUMO

Objetivo: Avaliar capacidade seladora de um cimento resinoso autoadesivo como tampão cervical para clareamento interno. Métodos: Quarenta incisivos inferiores bovinos recém-extraídos foram tratados endodonticamente. Após 72 horas, foi realizada a desobturação parcial do canal radicular para confecção de tampão cervical dividido em quatro grupos aleatório (n = 40), cada um contento dez amostras (n = 10), com os seguintes materiais: cimento resinoso autoadesivo, cimento resinoso adesivo, cimento de óxido de zinco sem eugenol com presa por água e cimento de ionômero de vidro quimicamente ativado (grupo controle). Após 24 horas de presa dos materiais, os elementos dentais foram submetidos ao clareamento interno com perborato de sódio misturado com água destilada pelo período de 7 dias em câmara umidificadora a 37 ºC. Posteriormente, o material clareador foi removido e um corante (fucsina básica 0,5%) foi colocado no interior da câmara pulpar, sendo renovado de 8 em 8 horas, pelo período de 24 horas. Os elementos dentais foram seccionados no sentido longitudinal em máquina de corte para avaliação quantitativa em um microscópio óptico sob aumento de 20x. O grau de penetração do corante foi analisado ao longo do tampão cervical (topo até base). Resultados: Não houve diferença significativa entre os materiais tamponantes utilizados (p = 0,5997). Conclusão: O cimento resinoso autoadesivo apresentou baixo grau de infiltração, sendo uma opção de material alternativo com finalidade de tampão cervical.


Aim: To evaluate the sealing ability of a self-adhesive resin cement as a cervical barrier for internal bleaching. Methods: Forty recently extracted bovine lower incisors were endodontically treated. After 72 hours, partial disobturation of the root canal was performed, a cervical barrier was placed, and the teeth were divided into four random groups (n = 40), each containing ten samples (n = 10), using the following materials: self-adhesive resin cement, adhesive resin cement, zinc oxide cement without eugenol cured by water, and chemically activate glass ionomer cement (control group). Twenty-four hours after the materials were cured, the teeth were subjected to internal bleaching with sodium perborate and distilled water for a period of seven days in a humidified chamber at 37°C. After, the bleaching material was removed and a dye (0.5% basic fuchsin) was placed inside the pulp chamber and renewed every eight hours for a period of 24 hours. The teeth were sectioned longitudinally in a cutting machine for quantitative evaluation using an optical microscope under 20x magnification. The degree of dye penetration was evaluated through the cervical barrier (top to bottom). Results: No significant difference was observed among the cervical barrier materials used in this study (p = 0.5997). Conclusion: The self-adhesive resin cement had low degree of leakage and represents an alternative material option to be used as a cervical barrier.


Assuntos
Clareamento Dental , Cimentos de Resina , Cimentos Dentários/análise , Endodontia , Clareadores Dentários/análise , Cimentos de Ionômeros de Vidro
3.
Odontol. vital ; (33)dic. 2020.
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1386434

RESUMO

Resumen Introdución: En general el Ionómero de vidrio tiene algunas desventajas en la parte clínica, como es la fragilidad y la sensibilidad inicial a la humedad, lo que puede causar una disminución de la vida útil de la restauración. Estos efectos que sufre el ionómero como la sorción de humedad y la solubilidad a los ácidos puede causar daño a la restauración, facilitar su fractura y filtración marginal, lo que puede conllevar a una recidiva de caries y pérdida de sus propiedades. Objetivo: comparar in vitro la sorción de humedad y disolución ácida de dos ionómeros de restauración. Método: Se elaboraron 20 muestras de ionómero de vidrio Ketac molar y 20 de Fuji II. Se realizó una primera medición del peso con balanzas de precisión, obteniéndose un peso inicial. Los especímenes fueron sumergidos en agua destilada durante 24 horas, almacenadas en un calefactor; cada muestra fue pesada con una balanza de precisión, estableciéndose el porcentaje de humedad sorbida a partir del peso inicial. Posteriormente las muestras fueron sumergidas en solución de ácido cítrico al 3% durante 24 horas, para volver a ser pesadas, evaluándose la perdida de material por acción erosiva del ácido en porcentaje de peso. Conclusiones: La sorción de humedad en peso fue de 2,59% en el ketac molar y 1,45% en el Fuji II; al comparar las muestras mediante la prueba t, se obtuvo diferencias estadísticamente significativas. El porcentaje de pérdida de material por acción erosiva del ácido fue de 10,81% para Ketac molar y 18,62% para el Fuji II; al comparar las muestras mediante la prueba t, se obtuvo diferencias estadísticamente significativas. Se concluyó que la sorción de humedad fue mayor en el Ketac molar y la mayor solubilidad a la acción del ácido cítrico fue del Fuji II.


Abstract Introduction: Glass Ionomer has certain clinical disadvantages, such as fragility and moisture sensitivity, which might reduce the restauration´s lifespan. This effects, such as water absorption and acid solubility may damage the restauration, cause fracture and marginal filtration, this could trigger cavity relapse and the loss of the correct mechanical properties. Objective: Compare in vitro moisture sorption and acid solution of two restoration ionomers. Method: 20 samples of Ketac molar glass ionomer and 20 of Fuji II were made. A first weight measurement was made with precision scales, obtaining an initial weight. The specimens were submerged in distilled water for 24 hours, stored in a heater; Each sample was weighed with a precisión balance, establishing the percentage of moisture absorbed from the initial weight. Subsequently, the samples were submerged in 3% citric acid solution for 24 hours, to be re-weighed, evaluating the loss of material due to erosive action of the acid in percentage of weight. Conclusions: The moisture sorption by weight was 2.59% in the molar ketac and 1.45% in the Fuji II; When comparing the samples using the t-test, statistically significant differences were obtained. The percentage of material loss due to erosive action of the acid was 10.81% for molar Ketac and 18.62% for Fuji II; When comparing the samples using the t-test, statistically significant differences were obtained. It was concluded that the moisture sorption was higher in the molar Ketac and the greatest solubility to the action of citric acid was Fuji II.


Assuntos
Cimentos de Ionômeros de Vidro/análise , Erosão Dentária , Cimentos Dentários/análise
4.
Rev. Soc. Odontol. La Plata ; 29(57): 15-19, dic. 2019. ilus
Artigo em Espanhol | LILACS | ID: biblio-1049929

RESUMO

Se determinó la solubilidad en agua en ensayos in-vitro de un sellador para uso endodóntico a base de un conglomerado de trióxidos minerales (MTA), marca Endosealer® (Densell SA) de acuerdo a la norma UNE-EN ISO 6876:2012. En el ensayo de solubilidad en agua durante 24 hs se encontró pérdida de masa (3,3 %) y la presencia de sólidos en las aguas de lavado (6,4 %). Esto indica que durante el ensayo ocurre la solubilización de parte del material y la incorporación de agua, lo que no permite establecer un valor real de la solubilidad.(AU)


Solubility of a commercial endodontic sealer (Endosealer® (Densell SA)) was performed according to the UNE-EN ISO 6876:2012. The results show a mass loss of 3.3 % and 6.4 % of solid in the test solution. These indicate that during the solubility test part of the material solubilizes and an actual value of solubility cannot feasible be determined


Assuntos
Materiais Restauradores do Canal Radicular , Cimentos Dentários/análise , Cimentos Dentários/química , Solubilidade , Materiais Dentários
5.
Rev. cuba. estomatol ; 56(3): e1420, jul.-set. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1093233

RESUMO

RESUMEN Introducción: Los cementos selladores en endodoncia deben tener estabilidad dimensional para controlar la contaminación por microorganismos. Objetivo: Determinar la estabilidad dimensional del cemento endodóntico Adseal® en humedad relativa. Métodos: se realizó un estudio in vitro, mediante las especificaciones de la Organización Internacional de Normalización (ISO) 6876:2001. Se emplearon cinco moldes cilíndricos, los cementos fueron sometidos a humedad relativa, se utilizaron dos gabinetes para mantener la temperatura de 37° ± 1 ºC, monitoreados con un termohigrómetro. Se utilizó el estereomicroscopio para la medición en la 1ra, 2da, 3ra y 4ta semanas. Se utilizó la prueba de Friedman para evaluar la estabilidad dimensional; el nivel de significancia fue del 5 por ciento. Resultados: el Adseal® en humedad relativa en la 1ra semana registró una expansión leve 0,07 por ciento (11 024,2 µm), en la 2da semana presentó una leve contracción -0,06 por ciento (11 009,2 µm), en la 3ra y 4ta semanas se registró una mayor expansión de longitud por encima de la norma ISO de 1,46 por ciento (11177,4 µm) y 2,76 % (11 320,6 µm), respectivamente, lo cual resultó estadísticamente significativo durante el periodo de exposición (p= 0,003). Para el diámetro y el perímetro se presentó un aumento por encima del 1 por ciento a la primera y cuarta semanas. Conclusiones: Existen cambios dimensionales en expansión de longitud en el cemento Adseal® en las primeras cuatro semanas en humedad relativa, con mayores cambios por encima de la norma en la 3ra y 4ta semanas. Para el diámetro y el perímetro se presentó un aumento por encima de la norma a la 1ra y 4ta semanas(AU)


ABSTRACT Introduction: Endodontic sealing cements should have dimensional stability to control contamination by microorganisms. Objective: Determine the dimensional stability of endodontic cement Adseal® under relative humidity conditions. Methods: An in vitro study was conducted based on International Organization for Standardization specifications (ISO) 6876:2001. Five cylindrical molds were used. The cements were subjected to relative humidity conditions and two cabinets were used to keep the temperature at 37 °C ± 1 ºC, monitored with a thermo-hygrograph. Measurements were taken in the 1st, 2nd, 3rd and 4th weeks with a stereo microscope. The Friedman test was used to evaluate dimensional stability with a significance level of 5 percent. Results: Under relative humidity conditions, Adseal® displayed a slight 0.07 percent (11 024.2 µm) expansion the first week, a slight -0.06 percent (11 009.2 µm) contraction the second week, and greater length expansion above the ISO standard of 1.46 percent (11 177.4 µm) and 2.76 percent (11 320.6 µm), respectively, in the third and fourth weeks, which was statistically significant during the exposure period (p= 0.003). Regarding diameter and perimeter, an increase above 1 percent occurred in the first and fourth weeks. Conclusions: Length expansion dimensional changes were registered for Adseal® cement during the first four weeks under relative humidity conditions, with greater changes above the standard in the third and fourth weeks. Regarding diameter and perimeter, an increase above the standard occurred in the first and fourth weeks(AU)


Assuntos
Humanos , Fenômenos Químicos , Cimentos Dentários/análise
6.
Rev. odontol. UNESP (Online) ; 48: e20190112, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1099186

RESUMO

Abstract Introduction Flow and filling ability of root canal sealers are indispensable for hermetic sealing of the root canal. Micro-computed tomography (micro-CT) can be used as a complementary methodology to evaluate such properties. Objective To evaluate the flow and filling ability of AH Plus, Endofill and Sealapex by conventional methodology and micro-CT. Material and method The flow of the sealers was analyzed according to ISO 6876/2012 and complemented by the area evaluation. Glass plates were manufactured with diameters of 1×1×2 mm and 1×1×1 mm (length, width and height), with a central cavity and four grooves in the horizontal and vertical directions. Each material was placed in the central cavity. Another glass plate and a metal weight were placed on the cement and kept for 10 minutes. The glass plate/sealer set was scanned using micro-CT. The flow was calculated by linear measurement of the material in the grooves. The central filling (mm3) was calculated in the central cavity and the lateral filling was measured up to 2 mm from the central cavity. Data were submitted to ANOVA/Tukey tests (α=0.05). Result All evaluated sealers presented flow according to ISO 6876 standards. The materials showed central cavity filling capacity higher than 80% and lateral filling greater than 75%. There was no difference in flow (mm and mm2) and in the filling ability (mm3) provided by the materials (p>0.05). Conclusion All evaluated root canal sealers showed adequate flow and filling capacity, suggesting their clinical application.


Resumo Introdução Escoamento e capacidade de preenchimento de cimentos obturadores são indispensáveis para um selamento hermético do canal radicular. Microtomografia computadorizada (micro-CT) pode ser utilizada como uma metodologia complementar para avaliação de tais propriedades. Objetivo Avaliar escoamento e capacidade de preenchimento de AH Plus, Endofill e Sealapex, por meio de metodologia convencional e micro-CT. Material e método O escoamento dos cimentos foi analisado de acordo com as normas ISO 6876/2012 e complementado pela avaliação em área. Placas de vidro foram confeccionadas nos diâmetros de 1×1×2 mm e 1×1×1 mm (comprimento, largura e altura), com uma cavidade central e quatro canaletas nas direções horizontal e vertical. Cada material foi colocado na cavidade central. Outra placa de vidro e um peso de metal foram colocados sobre o cimento e mantidos por 10 minutos. O conjunto placa de vidro/cimento foi escaneado usando micro-CT. O escoamento foi calculado por medição linear do material nas canaletas. O preenchimento (mm3) central foi calculado na cavidade central e o preenchimento lateral foi medido até 2 mm a partir da cavidade central. Os dados foram submetidos aos testes ANOVA/Tukey (α=0.05). Resultado Todos os cimentos avaliados apresentaram escoamento de acordo com as normas ISO 6876. Os materiais mostraram capacidade de preenchimento da cavidade central superior a 80% e preenchimento lateral superior a 75%. Não houve diferença no escoamento (mm e mm2) e na capacidade de preenchimento (mm3) proporcionada pelos materiais (p>0.05). Conclusão Todos os cimentos obturadores avaliados mostraram adequado escoamento e capacidade de preenchimento, sugerindo a aplicação clínica dos mesmos.


Assuntos
Materiais Restauradores do Canal Radicular , Cimentos Dentários/análise , Microtomografia por Raio-X/métodos , Tratamento do Canal Radicular
7.
São José dos Campos; s.n; 2018. 73 p. il., tab., graf..
Tese em Português | BBO, LILACS | ID: biblio-1016217

RESUMO

O objetivo desta pesquisa foi avaliar a influência da utilização ou não do bond do sistema adesivo Adper Scotchbond Multiuso(A) e o bond Gluma da Heraeus(G) na resistência de união entre as resinas do tipo flow Filtek Bulk Fill Flow(F) e X-tra base (X) como base e uma convencional nanoparticulada Z350 XT(Z)) como cobertura. Simulando assim seu uso em reparos de restaurações diretas em dentes posteriores. Foram confeccionados 120 espécimes em resina composta do tipo flow no formato tronco-cônico com as dimensões de 2mm base menor, 4mm de altura e 4 mm de base maior. 60 Filtek Bulk Fill(F) e 60 Xtra base (X). Metade de cada grupo (n=30) foi envelhecida por termociclagem 5.000 ciclos de 5°C a 55°C, (FE, XE), a outra metade não sofreu envelhecimento (FN e XN). Esses espécimes foram divididos em 3 subgrupos (n=10), sobre a base menor dessas 10 amostras foi aplicado o Bond de cada sistema adesivo após condicionadas pelos seus respectivos ácidos nos tempos preconizados pelos fabricantes. As outras 10 unidades de cada grupo não receberam qualquer sistema adesivo. Na simulação do reparo as duas primeiras metades em teflon foram invertidas ficando a área menor voltada pra cima. Sobre essa face foram colocadas outras duas metades em teflon com a área menor voltada para baixo. Foi inserida então a resina Z350 pela técnica incremental e fotopolimerizada por 20s a 800mw/cm². Após 24h de armazenamento em água destilada, em estufa bacteriológica os espécimes, agora com formato de ampulheta, foram tracionados na máquina de ensaios universais (EMIC). Todos os espécimes fraturados tiveram o tipo de falha analisados ao estereomicroscópio e também ao microscópio eletrônico de varredura (MEV). Os dados coletados no ensaio de tração foram analisados através de ANOVA 3- fatores e teste de Tukey (p<5%). Houve diferença significativa (p<5%) para a variável aplicação de sistema adesivo para a resina Filtek Bulk Fill flow que apresentou médias maiores (24,99 ± 4,3 MPa) quando comparadas ao grupo no qual não foi aplicado adesivo (18,20 ± 5,31 MPa). O mesmo não ocorreu com a resina X-tra base, na qual o fator adesivo não interferiu significantemente. Quando comparado o desempenho das resinas Filtek Bulk Fill flow e X-tra base (26,99 ± 6,11 MPa) sem aplicação de sistema adesivo, também se verificou diferença significativa, o que não ocorreu para a resina X-tra base quando comparados ambos os subgrupos. As falhas foram 100% adesivas para todos os grupos(AU)


The aim of our paper was to analyse the bonding influence of Adper Scotchbond Multipurpose Adhesive (A) and Heraeus Gluma universal bond (G), or no bond application, on bond strength between microhibrid Filtek Bulk Fill Flow (F) and nanohibrid X-tra base (X) as based composite resin and the conventional nanoparticulate Z350 XT (Z)) as cover. Simulating non-invasive repairs of direct restorations on posterior teeth. A total of 120 specimens were made from flow composite resin in the conical trunk format with the dimensions of 2x4x4, for 40s with Led-5 (N/S LD51803005) at 800mw/cm². Sixty Filtek bulk fill (F) and sixty X-tra base (X) were made. Half of each group (n=30) was aged by thermocycling 5,000 cycles from 5° C to 55° C, (FE, XE), the other half were not subjected to any aging procedure (FN, XN). These specimens were randomly divided into 3 subgroups (n = 10), on the smaller diameter of the 10 samples the Bond of each adhesive system were applied after conditioned by their respectively acids at the time recommended by the manufacturers. The other 10 units of each group did not receive any adhesive system. In the sequency of repair simulation the first two Teflon halves were turned up with the smaller diameter turned upwards. Above this face were placed two other halves in Teflon with the smaller diameter facing down. The Z350 repair composite resin were inserted by incremental technique and photopolymerized for 20s at 800mw/cm². After 24h of storage in distilled water in a bacteriological oven, the now hourglass-shaped specimens were drawn in the universal testing machine EMIC. All the fractured specimens had the type of failure analyzed in stereomicroscope. The most significant faulting specimens were evaluated with electronic microscope (MEV). The data collected at the traction test were analyzed through 3-factor ANOVA and Tukey's test (p <5%). There was a significant difference (p <5%) for the variable adhesive system application for Filtek Bulk Fill flow resin that presented averages (24.99 ± 4.3 MPa) when compared to the group in which no adhesive was applied (18.20 ± 5.31 MPa). The same did not occur with X-tra base resin, in which the adhesive factor did not interfere significantly. When comparing the performance of Filtek Bulk Fill Flow resins and X-tra base (26.99 ± 6.11 MPa) without application of adhesive system, a significant difference was also observed, which did not occur for X-tra base resin when compared both subgroups. Most of the failures were adhesive for all groups. Scanning electron microscopy images do not reveal any traces of discontinuity between the layers of the materials used (resin x resin or resin x adhesive)(AU)


Assuntos
Humanos , Cimentos Dentários/análise , Resistência à Tração , Resinas Compostas/administração & dosagem
8.
Rev. Salusvita (Online) ; 36(1): 99-121, 2017. ilus
Artigo em Português | LILACS | ID: biblio-876190

RESUMO

Introdução: atualmente os produtos à base de hidróxido de cálcio são amplamente utilizados e difundidos na odontologia em várias situações clínicas, desde capeador em exposição pulpar à pulpotomias, em virtude de suas propriedades físicas, mecânicas, do baixo custo e de seu próprio mecanismo de ação, representando assim, o material mais próximo do ideal. Objetivo: descrever os conceitos, os fundamentos e a aplicação clínica do Hidróxido de Cálcio e do MTA, por meio de uma revisão da literatura. Material e Métodos: foi realizada uma revisão da literatura, por meio de busca bibliográfica nas seguintes bases de pesquisa online: Lilacs, Scielo, PubMED/Medline e Bireme, com uso dos descritores: hidróxido de cálcio (calcium hydroxide); hidróxido de cálcio e MTA (calcium hydroxide and MTA) e MTA, rastreando artigos relevantes publicados entre o período de 2010 a 2015. Resultados e Discussão: materiais a base de hidróxido de cálcio, são biocompatíveis e apresentam propriedades antimicrobianas, anti-inflamatórias, estimulantes da formação de dentina esclerosada, de tecido ósseo mineralizado além de proteger a polpa contra estímulos termoelétricos e tóxicos, provenientes de alguns materiais restauradores, mantendo assim, a integridade pulpar. São amplamente utilizados para: proteção pulpar, pulpotomias, cimentação protética, forramento cavitário, apicificação e em casos de reabsorção radicular. As formas de apresentação desses materiais pode ser produtos na forma de pó, ou na forma de pastas, autoativadas ou fotoativadas. O Agregado Trióxido Mineral (MTA) apresenta muitas propriedades coincidentes com o hidróxido de cálcio, mas uma das suas principais desvantagens é seu alto custo, o que inviabiliza o rotineiro na clínica, esse material é apresentado na forma de pó e líquido, o qual é composto apenas por água destilada. Conclusão: Diante das várias opções de produtos presentes no mercado, recomenda-se ao profissional a escolha do melhor material para cada caso, incluindo seguir protocolos adequados durante a aplicação dos materiais para alcançar resultados clínicos satisfatórios.


Introduction: products of calcium hydroxide are largely used in a variety of dental clinical condition due to its physical and mechanical properties and its low cost as well as its rationelle. In this contexto, it representes a material close to the ideal. Objective: to describe the concepts, fundamentals and clinical application of Calcium Hydroxide and MTA, through a review of the literature. Materials and Methods: a review of the literature was carried out by means of bibliographic search in the following online databases: Lilacs, Scielo, PubMED/Medline and Bireme, using the descriptors: calcium hydroxide; Calcium hydroxide and MTA, and MTA, tracking relevant articles published between the period 2010-2015. Results and Discussion: materials based on calcium hydroxide, are biocompatible and exhibit antimicrobial, anti-inflammatory, stimulating properties of the formation of sclerosed dentin, of mineralized bone tissue, besides protecting the pulp against thermoelectric and toxic stimuli from some restorative materials, thus maintaining pulp integrity. They are widely used for: pulp protection, pulpotomies, prosthetic cementation, cavity lining, apicification and in cases of root resorption. The forms of presentation of such materials may be products in the form of powder, or in the form of pastes, either self-activating or photoactivated. The Mineral Trioxide Aggregate (MTA) has many properties that coincide with calcium hydroxide, but one of its main disadvantages is its high cost, which makes the routine in the clinic unfeasible. This material is presented in the form of powder and liquid, which is Composed only of distilled water. Conclusion: in view of the various product options present in the market, the professional is advised to choose the best material for each case, including following appropriate protocols during the application of the materials to achieve satisfactory clinical results.


Assuntos
Hidróxido de Cálcio/uso terapêutico , Hidróxido de Cálcio/farmacologia , Endodontia/instrumentação , Materiais Biocompatíveis , Literatura de Revisão como Assunto , Cimentos Dentários/análise , Capeamento da Polpa Dentária
9.
Dent. press endod ; 6(3): 41-45, Sept-Dec. 2016. ilus
Artigo em Português | LILACS, BBO | ID: biblio-846471

RESUMO

Objetivo: o objetivo deste estudo foi avaliar a solubilidade, pH e composição química do MTA branco em contato com sangue e soro fisiológico. Métodos: trinta réplicas de incisivos centrais superiores em acrílico, com retrocavidades com 3 mm de profundidade, foram preenchidas com MTA branco. Os espécimes foram individualmente inseridos em microtubos e divididos em três grupos (n = 10): no Grupo 1, as amostras não foram expostas a líquidos (grupo controle); no grupo 2, os microtubos receberam 1 mL de soro fisiológico; e no Grupo 3, receberam 1 mL de sangue humano fresco. As amostras foram armazenadas a 37°C durante 24 horas. A solubilidade foi avaliada volumetricamente, de modo que os espécimes foram escaneados por Micro-CT e individualmente imersos em 10 mL de água ultrapura; após 168 horas, novos escaneamentos foram realizados. O nível de pH foi mensurado após 168 horas. Secções das amostras com 2 mm de espessura foram analisadas por meio de espectroscopia de energia dispersiva, para avaliar a composição iônica. Os dados foram analisados estatisticamente pelos testes ANOVA e Tukey. Resultados: a solubilidade foi similar (p > 0,05) para todos os grupos. Após 168 horas, o pH foi significativamente maior para o Grupo 2, em comparação ao Grupo 3 (p < 0,05). Quanto à composição iônica, foi encontrada maior concentração de cálcio e o contato com sangue não interferiu na liberação de íons de cálcio. Conclusão: o contato do sangue e soro fisiológico com o MTA não influenciou na solubilidade, ambos favoreceram um pH alcalino, com o aumento da liberação de íons cálcio, com pequenas variações na composição iônica.


Assuntos
Humanos , Cimentos Dentários/análise , Materiais Dentários , Endodontia , Teste de Materiais , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X
10.
Dent. press endod ; 6(2): 21-27, May-Aug. 2016. ilus
Artigo em Português | LILACS, BBO | ID: biblio-846946

RESUMO

Objetivo: o objetivo do presente estudo foi avaliar se a etapa de processamento em que o cimento é obtido in uencia nas suas propriedades físico-químicas. Foram avaliados a composição química, o tempo de presa, solubilidade, pH e liberação de íons cálcio do cimento Portland (Grupo 1), que passa por todas as etapas do processamento; e do cimento que foi obtido na etapa de calcinação (Grupo 2). Métodos: para avaliação da composição química, foi utilizado um microscópio eletrônico de varredura na função EDS. Os testes de tempo de presa e solubilidade foram realizados de acordo com as normas #57 da ADA. Para determinação do pH e liberação de íons cálcio, foram utilizados um peagômetro e um espectrofotômetro de absorção atômica, respectivamente. Resultados: a composição química de ambos os cimentos apresentou maior quantidade de íons cálcio e silício; porém, o cimento Portland apresentou traços de enxofre. Com relação ao tempo de presa, o Grupo 2 apresentou média de tempo de presa estatisticamente menor do que o Grupo 1 (p < 0,05). Com relação à solubilidade, ambos os cimentos apresentaram valores dentro do que é recomendado pela ADA, que é de no máximo 3%; porém, houve diferença significativa, sendo o Grupo 2 mais solúvel (p < 0,05). Na análise do pH e liberação de íons cálcio, observou-se que ambos os cimentos promoveram alcalinização e liberação de íons cálcio, independentemente do tempo analisado. Conclusão: com base nos resultados obtidos, conclui-se que a etapa do processamento em que é obtido o cimento influencia em suas propriedades físico-químicas.


Assuntos
Humanos , Calcarea Silicata , Cimentos Dentários/análise , Cimentos Dentários/química , Fenômenos Químicos , Solubilidade
11.
Rev. Salusvita (Online) ; 35(2): 195-206, 2016. ilus, tab
Artigo em Português | LILACS | ID: biblio-827240

RESUMO

Introdução: em Endodontia, a busca pelo sucesso clínico a longo prazo depende do conhecimento das propriedades de diversos materiais odontológicos. Objetivo: avaliar o escoamento e extravasamento de cimentos endodônticos em canais laterais fabricados em blocos de resina (IM do Brasil LTDA): Métodos: foram testados 5 cimentos utilizados em Endodontia (AH Plus®, Pulp Canal Sealer®, Endomethasone®, Sealer 26® e Endofill®). Para o estudo in vitro, utilizou-se 20 blocos transparentes de canais simulados, onde cada bloco possuía 3 canais: cervical, médio e apical. Resultados e Discussão: o Edomethasone® apresentou menor porcentagem de escoamento (66,67%) em relação aos demais. Em relação ao extravasamento, os canais cervicais dos grupos Endomethasone® (50%) e Endofill® (50%) foram os mais expressivos. Conclusão: todos os cimentos testados apresentaram bom escoamento e extravasamento para obturação do sistema de canais radiculares. O Pulp Canal Sealer® obteve maior porcentagem e média de escoamento, obturando os canais cervicais, médios e apicais. O Endomethasone® apresentou menor porcentagem de escoamento e o AH Plus®, a menor média de escoamento em milímetros quando avaliados os canais apicais. (AU)


Introduction: In Endodontics, the search for long-term clinical success depends on the knowledge of properties of several dental materials. Aim: To evaluate the flow and extravasation of endodontic sealers inside of channels made with resin blocks (IM Brazil LTDA). Five endodontic sealers were tested (AH Plus, Pulp Canal Sealer, Endomethasone, Sealer 26 and Endofill). Material and Methods: For the in vitro study, we used 20 transparent blocks of simulated channels, where each block had 3 channels: cervical, middle and apical. The Edomethasone sealer presented a smaller percentage of flow (66.67%) compared to the others. With regard to extravasation, cervical channels of Endomethasone (50%) and Endofill (50%) groups showed the highest percentage of extravasation. Conclusions: All tested endodontic sealers had good flow and extravasation. The Pulp Canal Sealer was the one that had the highest percentage of average flow. The sealer Endomethasone presented the lowest percentage of flow and AH Plus the lowest average flow in millimeters when evaluated apical channels. (AU)


Assuntos
Obturação do Canal Radicular/instrumentação , Obturação do Canal Radicular/métodos , Cimentos Dentários/análise , Endodontia/instrumentação , Materiais Restauradores do Canal Radicular , Técnicas In Vitro , Teste de Materiais , Radiografia Dentária Digital
12.
São Paulo; s.n; 2016. 38 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO | ID: biblio-867924

RESUMO

O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo.


The aim of this study was to evaluate the influence of dentin tubule density of different depths in the bond stability of two high viscous glass ionomer cements (GIC). Twenty (third) molars were assigned into 6 experimental groups, according to the depth of dentin - proximal, superficial or deep occlusal occlusal and the GICs - Fuji IX (GC Corp.) and Ketac (TM) Molar Easy Mix (3M / ESPE). Initially, the teeth were cut to obtain slices approximately 1 mm thick for approximal, superficial and deep occlusal surfaces. Then it was performed a topographical analysis of sections of different depths surfaces and laser confocal microscopy (100X) to obtain averages of the tubular density at each depth. Polyethylene cannulae were then positioned on the pre-treated dentin sections and filled with GIC. The specimens were stored in distilled water for 24 h and 12 months at 37°C were then subjected to microshear bonding test (0.5 mm / min). After the test, a fracture analysis pattern was performed in stereomicroscope (400X). The data were submitted to ANOVA for repeated measures followed by the Tukey test (? = 5%). We found that the density of dentinal tubules at different depths of permanent molars, is inversely proportional to the bond strength of high viscosity glass ionomer cements. It was observed in all groups which bond strength after 24 hours is higher than in 12 months, indicating degradation of the interface over time.


Assuntos
Humanos , Masculino , Feminino , Cimentos Dentários/análise , Cimentos Dentários , Cimentos Dentários/efeitos adversos , Cimentos Dentários/metabolismo , Cimentos de Ionômeros de Vidro/análise , Cimentos de Ionômeros de Vidro , Cimentos de Ionômeros de Vidro/efeitos adversos , Cimentos de Ionômeros de Vidro/metabolismo , Cimentos de Ionômeros de Vidro/síntese química , Resistência Física
13.
Rev. Salusvita (Online) ; 35(1): 9-25, 2016. tab
Artigo em Português | LILACS | ID: lil-788577

RESUMO

Introdução: canais radiculares necrosados e não tratados se caracterizam pela presença de uma microbiota mista e polimicrobiana.O E. faecalis demonstra alta resistência a medicamentos usados durante o tratamento endodôntico, sendo um dos poucos microrganismos que tem demonstrado in vitro resistir ao efeito antibacteriano do hidróxido de cálcio. Além disso, é a espécie bacteriana mais frequentemente isolada, com prevalência variando entre 29% e 77% nos canais radiculares de dentes com insucesso endodôntico. Objetivo: avaliar a atividade antibacteriana dos cimentos endodônticos MTA Fillapex, Sealapex, Sealer 26 e Endofill puros e acrescidos de amoxicilina e ciprofloxacina frente a duas linhagens ATCC de Enterococcus faecalis (ATCC 29212 e ATCC 4083). Método: os testes foram realizados pela técnica de difusão radial dos cimentos aplicados diretamente no ágar, impregnados em discos de papel aplicados sobre o ágar e pelo teste de contato direto. Para a análise estatística utilizaram-se os testes de ANOVA e Tukey com nível de significância de 5%. Resultados e Discussão: os resultados mostraram que pela técnica da difusão radial, considerando os cimentos puros, o Sealapex foi o único que apresentou halo de inibição frente às duas linhagens. Já, quando da associação da amoxicilina e ciprofloxacina o MTA Fillapex demonstrou os melhores halos de inibição para as duas linhagens. Todos os cimentos tiveram a ação potencializada pela adição dos antibióticos (p<0,05). Pela técnica de difusão dos cimentos impregnados em discos de papel, o cimento Sealapex puro fresco revelou atividade antimicrobiana e também em todas as variáveis de tempo. Quando acrescidos os antibióticos, todos os cimentos tiveram a ação antimicrobiana potencializada pelas drogas, em todas as variáveis de tempo. Este mesmo resultado foi observado na técnica do contato direto dos cimentos com ambas as linhagens. Conclusão: a atividade antibacteriana, frente ao E. faecalis, dos cimentos MTA Fillapex, Endofill, Sealer e Sealapex acrescidos os antibióticos amoxicilina e ciprofloxacina, é potencializada mesmo após um longo período da presa dos cimentos.


Introduction: necrotic root canals and untreated are characterized by the presence of a mixed and polymicrobial flora. E. faecalis show high resistance to drugs used during endodontic treatment, one of the few microorganisms which have shown in vitro to resist the antibacterial effect of calcium hydroxide. Furthermore, it is the bacterial species most often isolated, with a prevalence ranging between 29% and 77%, in root canals of teeth with endodontic failure. Objective: the aim of this study was to evaluate the antibacterial activity of the sealers MTA Fillapex, Sealapex, Sealer 26 and Endofill, pure and loaded with amoxicillin and ciprofloxacin against two ATCC strains of Enterococcus faecalis (ATCC 29212 and ATCC 4083). Method: the tests were conducted by means of radial diffusion technique of the cement applied in to the agar, impregnated paper discs applied on the agar and by the direct contact test. For the statistical analysis, the ANOVA and the Tukey?s test were used at a 5% significance level. Results and Discussion: results showed that, through the technique of radial diffusion, regarding the pure cements, the Sealapex was the only one that showed inhibition halo for the two strains. However, considering the association of amoxicillin and ciprofloxacin Fillapex, the MTA showed better inhibition zones for the two strains. All cements had their actions enhanced by with addition of antibiotics (p <0.05). Through the technique of diffusion of cements impregnated in paper discs, the Sealapex pure fresh cement revealed an antimicrobial activity and also in all the variables of time. When loaded with antibiotics, all cements had the antimicrobial action potentiated by drugs in all variables of time. The same result was observed in the technique of direct contact of cement with both strains. Conclusionn: the antibacterial activity against the E. faecalis, of the cements MTA Fillapex, Endofill, Sealer and Sealapex loaded with the antibiotics amoxicillin and ciprofloxacin, is enhanced even after a long period of use of cements.


Assuntos
Enterococcus faecalis/efeitos dos fármacos , Cimentos Dentários/análise , Antibacterianos/uso terapêutico , Técnicas In Vitro , Teste de Materiais , Ciprofloxacina/efeitos adversos , Infecções por Bactérias Gram-Positivas , Amoxicilina/efeitos adversos
14.
Artigo em Inglês | IMSEAR | ID: sea-158249

RESUMO

Aim: The aim of this in vitro study was to observe and compare the microstructure of the adhesive interface between resin and dentin treated with Papacarie® using scanning electron microscopy (SEM). Materials and Methods: Totally, 10 human dentin slabs were randomly distributed into two groups. The control group (n = 5) was subjected to etching with 37% phosphoric acid for 20 s and washed for 30 s, dried with absorbent paper, and the bonding agent was applied along with low viscosity resin. In turn, the experimental group (n = 5) was subjected to the same procedure, but Papacarie® (Fórmula and Ação, São Paulo, Brazil) was added for 30 s prior to etching. Adper™ Single Bond 2 (3M ESPE, São Paulo, Brazil) adhesive was applied to both groups following manufacturer instructions. The specimens were prepared for observation under SEM with ×1.000, ×2.000, ×2.200 and ×5.000 magnification. The micrographs were evaluated with respect to the formation of the hybrid layer, thickness, shape and length of the tags and microtags. Results: In the experimental group there was the formation of more fine hybrid layer and tags with average of similar length to the control group; microtags in less number and without formation of lateral branches. The resin tags presented conical, smooth and uniform characteristics. Conclusions: When Papacarie® was used prior to the application of a bonding agent it could interfere with the formation of the hybrid layer without changing the length of the tag. Moreover, the morphology in the experimental group was found to be more uniform and regular.


Assuntos
Dente Pré-Molar , Dentina/análise , Dentina/terapia , Adesivos Dentinários/análise , Adesivos Dentinários/uso terapêutico , Cimentos Dentários/análise , Cimentos Dentários/uso terapêutico , Microscopia Eletrônica de Varredura/métodos , Papaína/uso terapêutico
15.
Artigo em Inglês | IMSEAR | ID: sea-156552

RESUMO

Background: Adhesive cementation is essential for the longevity of indirect esthetic restorations. However, polymerization shrinkage of resin cement generates stress, which may cause failures in the tooth–restoration interface. So, understanding of the biomechanics of resin cement is important for predicting the clinical behavior of an esthetic indirect restoration. Aims: To analyze the stresses generated during polymerization shrinkage of self‑curing resin cement in ceramic and in indirect resin (IR) restorations, using the finite‑element method (FEM). Settings and Design: Numerical study using the finite‑element analysis. Materials and Methods: A three‑dimensional (3D) model of a second molar restored with ceramic or IR onlay restoration was designed. The polymerization shrinkage of self‑curing resin cement was simulated in FEM software using an analogy between the thermal stress and the resulting contraction of the resin cement. The localization and values of tensile stresses in the dental structure, cement, and adhesive layer were identified. Results: The location and value of the tensile stresses were similar for the two restorative materials. High tensile stresses were identified in the axiopulpal wall and angles of the tooth preparation, with the major stresses found in the cement located in the axiopulpal wall. Conclusions: The high stresses values and their concentration in the angles of the prepared tooth emphasize the importance of round angles and the use of cements with lower rates of shrinkage.


Assuntos
Cimentos Dentários/análise , Cimentos Dentários/metabolismo , Análise de Elementos Finitos , Humanos , Polimerização , Resinas Sintéticas
16.
Braz. j. oral sci ; 12(4): 319-322, Oct.-Dec. 2013. tab
Artigo em Inglês | LILACS | ID: lil-701320

RESUMO

AIM: To evaluate the radiopacity and microhardness (KHN) of experimental dental adhesives (EX). The experimental adhesive resins of the present study were formulated based on the simplified adhesive system Ambar (FGM). METHODS: Five EX with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 30(EX30) e 50%(EX50)] were incorporated in a UDMA/HEMA adhesive (control). Adper Single BondTM 2 (SB, 3M ESPE) was used as a commercial reference. For the radiopacity (n=5), KHN (n=5), adhesive specimens were fabricated using a stainless steel mold. Data were submitted to one-way ANOVA and Tukey's test (α=0.05). RESULTS: The filler addition on the EX showed radiopacity similar to enamel and higher than SB. The EX25, EX35 and EX50 showed higher KHN values when compared to the commercial SB. EX25, EX35 and EX50 showed higher KHN values when compared to the commercial SB. CONCLUSIONS: The results of the present investigation suggest that the addition of zirconia nanoparticles seems to be a good alternative to produce radiopaque adhesives with increased microhardness.


Assuntos
Análise de Variância , Cimentos Dentários/análise , Meios de Contraste/análise , Nanopartículas/análise , Radiologia
17.
Belo Horizonte; s.n; 2013. 90 p. ilus.
Tese em Inglês, Português | LILACS, BBO | ID: lil-715932

RESUMO

A obturação do sistema de canais radiculares após a limpeza e modelagem é fundamental para o sucesso do tratamento endodôntico. Os materiais obturadores devem ter propriedades físicas e químicas favoráveis. Além disso, é altamente desejável que sejam biocompatíveis, porque, muitas vezes, são colocados em contato íntimo com os tecidos periapicais, através do forame e das comunicações acessórias apicais...


Assuntos
Humanos , Masculino , Feminino , Cimentos Dentários/análise , Macrófagos Peritoneais , Materiais Restauradores do Canal Radicular/análise , Fenômenos Químicos
18.
Acta odontol. venez ; 50(3)2012. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-676703

RESUMO

El objetivo de este estudio fue evaluar el comportamiento biológico de los cementos endodónticos Endofill, Endomethasone y Sealer 26, en tejido conjuntivo subcutáneo de ratones. Fueron establecidos tres grupos experimentales y un grupo control de cinco animales cada uno, en los períodos de 7, 21 y 60 días. Los cortes histológicos obtenidos fueron coloreados con Hematoxilina & Eosina y con tricrómico de Masson, para posteriormente ser evaluadas la reacción inflamatoria adyacente y la formación de tejido fibroso. Los datos obtenidos fueron sometidos al test estadístico de Kruskall-Wallis y Miller con 5% de nivel de significancia. El análisis microscópico mostró reacción inflamatoria más intensa en los períodos de 7 y 21días. A los 60 días hubo formación de una cápsula fibrosa densa para el cemento Endomethasone y parcialmente densa para los demás cementos. El análisis estadístico mostró diferencia estadísticamente significativa con mayor intensidad de reacción inflamatoria solamente para el grupo II (Endofill) en el período de 60 días en relación a los grupos I (control) y grupo III (Endomethasone). Todos los materiales presentaron reacción inflamatoria más intensa en los períodos inicial e intermediario, siendo que la Endomethasone presentó los mejores resultados.


The aim of this study was to evaluate the biological behavior of the root canal filling sealers: Endofill, Endomethasone and Sealer 26 when in contact with the subcutaneous connective tissue of rat. For the study one control and three experimental groups were used. A total of 15 animals were divided into 5 for each period: 7, 21, and 60 days. The obtained histological sections were processed and stained using the hematoxiline & eosine technique. The histological sections were subjective and comparatively analyzed using optic microscopy. The intensity of the inflammatory reaction and the level of fibrosis of the tissue were registered. The results were registered in scores and statistical analysis by KRUSKAL-WALLIS p<0,05 and MILLER methods. The statistical analysis revealed that in the period of 60 days, there was statistical significance to group II (Endofill) between group (control) and III (Endomethasone) with mononuclear cells into connective tissue. All materials promoted inflammatory reaction more intense at 7 and 21 days with the Endomethasone showing the best results.


Assuntos
Animais , Camundongos , Cavidade Pulpar/lesões , Cimentos Dentários/análise , Teste de Materiais/métodos
19.
Acta odontol. venez ; 50(4)2012. tab
Artigo em Espanhol | LILACS | ID: lil-678998

RESUMO

El objetivo fue analizar in vitro la resistencia de la unión al cizallamiento de sistemas adhesivos convencional y autocondicionante sobre la superficie de esmalte y dentina después del proceso erosivo ocasionado por una bebida ácida. Cuarenta incisivos bovinos fueron seccionados y desgastados hasta obtener superficies planas en esmalte y dentina. Sobre estas, fue simulado un proceso erosivo utilizando Coca-Cola® por 10 días, 4 veces al día durante 10 min. Después, las muestras fueron divididas en 4 grupos: G1-esmalte y G2-dentina, ambas superficies hibridizadas con adhesivo convencional (Adper Single Bond II); G3-esmalte y G4-dentina, hibridizados con sistema autocondicionante (Clearfil SE Bond). Cilindros de resina compuesta (Filtek Flow Z350) con 2 mm. de altura por 0,8 mm. de diámetro fueron confeccionados y almacenados en agua deionizada a 37º C por 24h. Terminado el período, fueron sometidos al test de microcizallamiento en Emic DL 2000 con una velocidad de 1mm/min. hasta la fractura. Los resultados fueron sometidos al análisis estadístico (ANOVA One-way) y las medias comparadas por el Teste post-hoc Games-Howell. Los grupos G1 y G3 presentaron los mayores valores medios (11,92 e 14,93MPa respectivamente) con diferencia estadística entre si (p<0.05). Los grupos G2 y G4 presentaron los menores valores (2,35 e 5,50MPa respectivamente) con diferencias estadísticas entre si (p<0.05). Se concluye que los sistemas adhesivos testados actuaron efectivamente sobre el esmalte después de la erosión, no siendo tan eficaz en la dentina, probablemente, debido al over etching


The aim of the present study was to verify the shear bond strength of total and self-etching systems on the surface of enamel and dentine after erosive process. 40 bovine incisors were sectioned and finished until the surfaces got planned in enamel and dentine. On these, erosive process was simulated by using Coke® for 10 days, 4 times by day during 10 min. After, the samples were divided in 4 groups: G1-enamel and G2-dentine, both surfaces were hybridized with total-etching adhesive system (Adper Single Bond II); G3-enamel and G4-dentine were hybridized with self-etching system (Clearfil SE Bond). Resin composite cylinders (Filtek Flow Z350) with 2 mm of height for 0,8 mm of diameter were constructed on these hybridized surfaces and after they were stored in distilled water at 37ºC for 24h. Subsequently, they were submitted to the microshear test in Emic DL 2000 with speed of 1mm/min until failure. The results were submitted to the statistical analysis (ANOVA One-way) and the means were compared by the Test post-hoc Games-Howell. The groups G1 and G3 presented the highest mean values (11.92 and 14.93MPa respectively) however they differed statically itself (p<0.05). By the other hand, the groups G2 and G4 showed the lowest mean values of bond strength (2.35 and 5.50MPa respectively) and they were statistically differents (p<0.05). It can be concluded that both adhesive systems acted effectively on the enamel after erosion process, but on dentin the adhesives were not so efficient due to over etching


Assuntos
Animais , Bovinos , Cimentos Dentários/análise , Esmalte Dentário , Erosão Dentária/veterinária , Selantes de Fossas e Fissuras/análise
20.
Dent. press endod ; 2(2): 37-41, 2012. tab, ilus
Artigo em Português | LILACS, BBO | ID: lil-686402

RESUMO

Objetivo: o objetivo desse estudo in vitro foi avaliar a infiltração marginal coronária após o preparo para retentor em dentes obturados com três diferentes cimentos,de acordo com o período entre a obturação do canal radicular e o preparo para retentor. Métodos: Noventa dentes humanos recentemente extraídos foram limpos e instrumentados e, então, obturados com Sealapex, Endométhasone ou TopSeal. Brocas Gates-Glidden foram utilizadas para o preparo imediato de 10 dentes de cada cimento até manter 5mm de obturação remanescente.Sessenta raízes obturadas foram incubadas a 37°C emmeio úmido por 30 e 60 dias para serem, depois, preparadas para os retentores como descrito anteriormente.A superfície externa de cada raiz foi coberta com Araldite. Os espécimes foram imersos em corante azul de metileno a 2% sob vácuo por 24h, para então poderem ser analisados. A infiltração foi mensurada pelo software Sigma Scan da parte superior da obturação à porção apical alcançada pelo corante. Resultado: o Sealapexe o TopSeal apresentaram menor infiltração após o preparo para retentor do que o Endométhasone. O preparo imediato para o retentor apresentou menor infiltração do que o preparo para o retentor após 30 e 60 dias da obturação do canal radicular


Assuntos
Humanos , Análise de Variância , Cimentação , Cimentos Dentários/análise , Infiltração Dentária , Obturação do Canal Radicular/métodos , Técnica para Retentor Intrarradicular , Preparo de Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA